SciDoc Publishers | Open Access | Science Journals | Media Partners


International Journal of Dentistry and Oral Science (IJDOS)  /  IJDOS-2377-8075-08-7060

Comparative Evaluation Of Dentin Crack Formation After Root Canal Preparation Using 3 Different Rotary Files - Invitro Study


Krishna Kanth Jaju1, Delphine Pricilla Antony S. MDS2, Pradeep Solete3*

1 Post Graduate student, Department of Conservative dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai-77
2 Senior Lecturer, Department of Conservative dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai-77
3 Reader, Department of Conservative dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai-77


*Corresponding Author

Pradeep Solete,
Reader, Department of Conservative dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai-77
E-mail: pandu.pradeep@gmail.com

Received: May 04, 2021; Accepted: July 09, 2021; Published: July 15, 2021

Citation:Krishna Kanth Jaju, Delphine Pricilla Antony S. MDS, Pradeep Solete.Comparative Evaluation Of Dentin Crack Formation After Root Canal Preparation Using 3 Different Rotary Files - Invitro Study. Int J Dentistry Oral Sci. 2021;8(6):3209-3213.doi: dx.doi.org/10.19070/2377-8075-21000654

Copyright:Pradeep Solete©2021. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.



Abstract

Introduction : The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: ProTaper Gold, TruNatomy and ProFit S3 at different instrumentation lengths. The aim was to evaluate and compare the incidence of dentinal crack formation after root canal preparation with ProTaper Gold, TruNatomy and ProFit S3 files.

Methodology: Forty Five extracted single-rooted premolars with straight, single root canals were selected for the study. The specimens were randomly assigned to three groups, with 15 samples in each group. The root canal preparation for the three groups was done with ProTaper Gold, TruNatomy and ProFit S3, respectively, following which the specimens were horizontally sectioned at 3, 6, and 9 mm from the apex. Sectioned samples were viewed under a stereomicroscope to determine the presence or absence of dentinal cracks. The data were analyzed using one-way ANOVA and Chi-square tests.

Results: TruNatomy and ProFit S3 files produced lesser number of cracks than ProTaper Gold. However, there was no statistically significant difference among the three groups at 3 mm,6 mm and 9mm (P > 0.05). It was evident that all files produced dentin cracks but it was not statistically significant.

Conclusions: ProTaper Gold, TruNatomy and ProFit S3 rotary files may cause dentinal cracks. ProTaper Gold, ProFit S3 files tend to produce more dentinal cracks than TruNatomy files.



1.Keywords
2.Introduction
6.Conclusion
8.References


Keywords

Dentin crack; ProFit S3; ProTaper Gold; Rotary files; TruNatomy.


Introduction

Endodontic diseases are associated with multiple bacterial infections. Root canal preparation is one of the most important steps in successful root canal treatment [1].

The main objective of root canal treatment is to eliminate inflamed and necrosed pulp tissue from the radicular portion, shape the dentinal walls to ease irrigation and to fill it with an inert material, maintaining the anatomy of the root canal system, and keep sound dentin for a prolonged period [2]. However, the complex canal anatomy causes instrumentation challenges, which may prevent adequate disinfection of the root canal system or cause procedural errors such as instrument separation, transportation, ledges, or perforations [2,3].

In recent times, rotary nickel-titanium (NiTi) instruments have completely changed the way root canal preparations are carried out, there are several nickel-titanium (NiTi) file systems used within the field of dentistry. NiTi rotary file systems have good flexibility which reduces the incidence of iatrogenic errors in the danger zone, ledge formation, perforation, and transportation of canals. Thus contributing to the better efficiency and safety of the root canal preparation [2-4]. Several approaches have been developed by the manufacturer to improve the flexibility and resistance to fracture of NiTi rotary endodontic instruments [2-6]. These approaches include modification of the instrument's cross-sectional design, decreasing the taper all over the length of the cutting blade, and enhancement of the manufacturing process by use of new alloys that provides improved mechanical properties[2-5].

NiTi rotary instruments have the advantages of increased flexibility and shortened working time, while instrument separation and dentinal crack formation are their major disadvantages[2-7]. Root canal preparation procedures can damage the root canal dentin causing dentinal cracks. Dentinal cracks occur when the tensile stress of the root canal wall exceeds that of the dentin[8]. Dentinal microcracks under repeated occlusal forces have the potential to develop into vertical root fracture, which is one of the most frustrating complications of endodontic therapy, often leading to tooth extraction[9]. Kim et al., established a possible relationship between the design features of NiTi rotary instruments, the incidence of the vertical root fractures[10] and concluded that apical stress and strain concentration induced during root canal preparation is influenced by the design features of the rotary file. Ananya Guha et al. compared the incidence of dentinal crack formation after root canal preparation with Neoendo flex and Mani silk files[11]. She concluded that Both hand K files and NiTi rotary instruments may cause dentinal cracks. Mani silk and K-file tend to produce fewer dentinal cracks than Neoendo Flex files.

ProTaper Gold (Dentsply, Tulsa Dental Specialties, Tulsa, OK, USA) NiTi rotary system was developed with proprietary advanced metallurgy. ProTaper Gold files exhibit a convex triangular cross-section[11,12]. It has a progressively tapered design to improve the cutting efficiency and safety. ProTaper Gold files may appear slightly curved when removed from the package due to their metallurgy. ProTaper Gold system has been metallurgically enhanced through heat treatment technology.

TruNatomy (TN; Dentsply Sirona, Maillefer, Ballaigu/es, Switzerland) is a novel file system manufactured from a 0.8 mm NiTi wire, followed by special heat treatment. TruNatomy files exhibit an Off-centered cross-section, Operates at a higher speed with less torque. It is claimed that TruNatomy has a reduced risk of separation due to the increased resistance to cyclic fatigue and flexibility[12].

Profit S3 (PS3) (Kedo Dental, India) is based on Blue Technology, It is a novel heat-treated rotary file system with a titanium oxide coating. It has a variable taper design with a rectangular cross-section. Profit S3 has two-point contact, thereby reducing the apical extrusion of debris. PS3 has good flexibility, increased resistance to fracture, and shape memory [14]. It has a variably variable taper, which varies between 4% and 8%[13].

In the literature, there is no data about the influence of these novel rotary NiTi files on dentin crack formation after root canal preparation at different instrumentation lengths using ProTaper Gold, TruNatomy, and ProFit S3 files. Thus, the purpose of the present study is to observe the incidence of dentin crack formation after root canal preparation at different instrumentation lengths performed with the newly introduced ProTaper Gold, TruNatomy, and ProFit S3 files systems under stereomicroscope. Previously our team has a rich experience in working on various research projects across multiple disciplines [14-28] Now the growing trend in this area motivated us to pursue this project.


Materials and Methods

Forty Five teeth were randomly assigned to three groups of [15] teeth (n = 15) each. Working length was measured by inserting a No. 10 K-file (Mani, Japan) till it was just visible at the apical foramen and then subtracting 1 mm from the measurement. A glide path was prepared using 10/02 and 15/02 K-file (Mani, Japan). Apical preparation was completed up to size 25 of each system. 20 ml of 5% sodium hypochlorite (Paras Chemical Industries, Pune) with 27G side-vented needles (Prime Dental Products Private Limited) was used for irrigation for each specimen.

Group 1: ProTaper Gold

Root canals were prepared using ProTaper Gold files attached to an endomotor (X-Smart Plus, Dentsply) according to the manufacturer's instructions at speed of 350 rpm and a torque of 1.5 Ncm. Coronal flaring was done with (30/08) file. Apical shaping was done with 20/06 and 25/06 up to the full working length.

Group 2: TruNatomy

Root canals were prepared using TruNatomy files attached to an endomotor (X-Smart Plus, Dentsply) according to the manufacturer's instructions at speed of 500 rpm and a torque of 1.5 Ncm. Coronal flaring was done with (30/08) file. Apical shaping was done with 20/06 and 25/06 up to the full working length.

Group 3: ProFit S3

Root canals were prepared using a standard pack of ProFit S3 attached to an endo motor (X-Smart Plus, Dentsply) according to manufacturer's instructions in gentle in and out motion at speed of 300 rpm and a torque of 2.6 Ncm. Coronal shaping was done using (25/08). Apical shaping was done using 20/06 and 25/06 up to the full working length.

Sectioning And Microscopic Examination

Roots were sectioned perpendicular to the long axis of the teeth, using a diamond disc under water cooling at 3, 6, and 9 mm from the apex and each section was stained with 2% methylene blue (Merck, India) for better visualization. Sectioned root slices were viewed under a stereomicroscope at ×25 magnification. Digital images of each section were analyzed using an image analysis system (Chroma Systems Pvt. Ltd., India) attached to the stereomicroscope. Each sectioned slice was observed by a single examiner to check the presence or absence of dentinal cracks.

Two distinct categories were made according to the method given by Karatas et al.

? Crack – Any lines, microcracks, or fractures that were present in the root dentin

? No crack – Root dentin devoid of craze lines, microcracks on the external surface of the root, and microcracks on the internal surface of the root canal wall.

Statistical Analysis

One-way ANOVA was used to analyze the data using SPSS Statistics Software (version 23.0 - IBM) with the level of significance set as P < 0.05.


Results and Discussion

Dentinal cracks were observed in all three groups. [Figure 1] represents a bar graph with the mean number of dentinal cracks at 3, 6, and 9 mm. Group 2 (TruNatomy) and Group 3 (ProFit S3) produced a lesser number of cracks as compared to Group 1 (Protaper Gold). According to one-way ANOVA, there was no statistically significant difference among the three file groups at 3,6 and 9 mm (P > 0.05).

One-way ANOVA test revealed no statistically significant difference between Group 2 and Group 3 (P > 0.05) and between Group 1 and Group 2 (P > 0.05). There was no statistically significant difference between Group 1 and Group 3 (P > 0.05). Overall, among the three rotary file systems, no statistically significant difference was seen in the crack formation. Protaper Gold Files produced more number of dentinal cracks across all sections than the other file systems used (P > 0.05). [Table 1] represents the percentage of teeth with a number of dentinal cracks for ProTaper Gold, TruNatomy and ProFit S3 files.

Biomechanical preparation is an important step to achieve success in endodontic treatment. At times, dentine damage can occur during procedures such as root canal cleaning, shaping and retreatment. The contact between the instrument and canal walls during preparation creates momentary stress concentrations in the root dentin, which may lead to dentinal defects from which vertical root fracture can originate. Instrument features such as tip design, cross-sectional geometry, taper, pitch design, and flute form may be related to dentinal crack formation.

In the present study, all root canal shaping files, produced microcracks in root dentin. These findings are in accordance with Yoldas et al. and Bürklein et al., who found cracks in the root canals prepared by rotary NiTi instruments but not in the root canals instrumented with hand K file[29,30,31]. According to Kesim et al, examination with any kind of magnification is not fully sufficient for detecting the preexisting craze lines or cracks that may be present on the inner surface of the root[30].

In the present study, cracks in the coronal region were more abundant than the cracks in the apical region for all the three groups, which is similar to previous studies done by Adorno et al. and Liu et al[32].

Bier et al.,stated that taper of files influences crack formation. The orifice opener used in our study is a larger taper (8%) instrument which causes more stress concentration in the root dentin, leading to microcracks[33]. Failure to identify pre-existing internal cracks that become visible after sectioning and the sectioning method itself could explain the reason for more microcracks in the coronal region.

Taper of files are reported to cause increased stress on canal walls[34]. Thus, the taper of the files could be a contributing factor in dentinal crack formation[33,34]. Additionally, a greater taper means a reduced remaining thickness of dentine. Wilcox et al. (1997) mentioned that the likelihood of root fracture increases with the amount of tooth structure removed[35]. Root canal instrumentation with larger instruments is associated with crack development and propagation of existing cracks[35,36].

In this study, ProtaperGold Files showed a more number of cracks than ProFit S3 and TruNatomy Files. All the file systems used in this study are heat-treated rotary NiTi files[37]. TruNatomy Files differ from Protaper Gold and ProFit S3 Files mainly differ in their taper and cross section. Protaper Gold and ProFit S3 Files are available in 6% taper, TruNatomy Files are available in 4% taper.

TruNatomy shaping file has an off-centered parallelogram crosssectional design with uniform taper, Protaper Gold has an convex triangular cross-sectional design combined with the flute design with its progressive tapers sequence along the shaft. ProFit S3 has a variable taper design with a rectangular cross-section, It has two-point contact.

Protaper Gold file has a unique convex triangular cross-sectional design, so it establishes three point contact with the root canal dentinal wall while it rotates in the canal during biomechanical preparation, Which transmits more tensile stresses to the root canal dentinal wall, leading to dentinal microcracks more than that of TruNatomy and ProFit S3 Files. On the other hand,TruNatomy Files has an off-centered parallelogram cross-sectional design, so each time the file rotates in the canal during biomechanical preparation; there is at least a one or two point contact between the instrument and the root canal wall. ProFit S3 Files has a offcentered rectangular cross-sectional design, so each time the file rotates in the canal during biomechanical preparation; there is at least a two point contact between the instrument and the root canal wall.

This is an in vitro study, so there is a possibility of the clinical scenario and outcome to be completely different. Versiani et al. stated that, in the clinical setting, it is highly unlikely that some ordinary root canal procedures could cause microcracks in a range of 40%–80%, as reported by most of the studies.

The possible limitations of our in vitro study are the sectioning method, difficulty in identifying internal pre-existing cracks, and the inability to standardize the speed and torque of both the rotary files used.

Our institution is passionate about high quality evidence based research and has excelled in various fields [38-48]



Figure 1: The graph shows the mean of canal centering ratio of Group I – Protaper Gold (purple - 3mm), Group II – TruNatomy, Group III - ProFit S3 at 3(Purple), 6(Green) and 9 (Grey)mm from the root apex of the teeth. There was no statistically significant difference between the three groups (P > 0.05).



Table 1: Represents the percentage of teeth with a number of dentinal cracks for ProTaper Gold, TruNatomy and ProFit S3 files.


Conclusion

Under the limitations of this investigation,the conclusion drawn is:

• Adhesion ofS. mutans was seen higher on the kidsSS crown than 3M SS crown.

• There was no significant difference between 3M and Kids crown.


References

  1. Bollen CM, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater. 1997 Jul;13(4):258-69. Pubmed PMID: 11696906.
  2. Stenudd C, Nordlund A, Ryberg M, Johansson I, Källestål C, Strömberg N. The association of bacterial adhesion with dental caries. J Dent Res. 2001 Nov;80(11):2005-10. Pubmed PMID: 11759011.
  3. Jalalian E, Mostofi SN, Shafiee E, Nourizadeh A, Nargesi RA, Ayremlou S. Adhesion of streptococcus mutans to Zirconia, Titanium alloy and some other restorative materials:“An in-vitro study”. Advances in Bioscience and Clinical Medicine. 2015 Apr 1;3(2):13-20.
  4. Bin AlShaibah WM, El-Shehaby FA, El-Dokky NA, Reda AR. Comparative study on the microbial adhesion to preveneered and stainless steel crowns. J Indian Soc Pedod Prev Dent. 2012 Jul-Sep;30(3):206-11. Pubmed PMID: 23263423.
  5. Hatta H, Tsuda K, Ozeki M, Kim M, Yamamoto T, Otake S, et al. Passive immunization against dental plaque formation in humans: effect of a mouth rinse containing egg yolk antibodies (IgY) specific to Streptococcus mutans. Caries Res. 1997;31(4):268-74. Pubmed PMID: 9197932.
  6. Pannu P, Gambhir R, Sujlana A. Correlation between the salivary Streptococcus mutans levels and dental caries experience in adult population of Chandigarh, India. Eur J Dent. 2013 Apr;7(2):191-195. Pubmed PMID: 24883025.
  7. Braga RR, Cesar PF, Gonzaga CC. Mechanical properties of resin cements with different activation modes. J Oral Rehabil. 2002 Mar;29(3):257-62. Pubmed PMID: 11896842.
  8. Shillingburg HT, Sather DA. Fundamentals of Fixed Prosthodontics [Internet].
  9. Messer LB, Levering NJ. The durability of primary molar restorations: II. Observations and predictions of success of stainless steel crowns. Pediatr Dent. 1988 Jun;10(2):81-5. Pubmed PMID: 3269527.
  10. Gibbons RJ, van Houte J. Bacterial adherence and the formation of dental plaques. InBacterial adherence 1980 (pp. 61-104). Springer, Dordrecht.
  11. Brambilla E, Cagetti MG, Gagliani M, Fadini L, García-Godoy F, Strohmenger L. Influence of different adhesive restorative materials on mutans streptococci colonization. Am J Dent. 2005 Jun;18(3):173-6. Pubmed PMID: 16158808.
  12. Kim DH, Kwon TY. In vitro study of Streptococcus mutans adhesion on composite resin coated with three surface sealants. Restorative dentistry & endodontics. 2017 Feb 1;42(1):39-47.
  13. Pereira-Cenci T, Del Bel Cury AA, Crielaard W, Ten Cate JM. Development of Candida-associated denture stomatitis: new insights. J Appl Oral Sci. 2008 Mar-Apr;16(2):86-94. Pubmed PMID: 19089197.
  14. Loesche WJ. Microbiology of Dental Decay and Periodontal Disease. In: Baron S, editor. Medical Microbiology [Internet]. Galveston (TX): University of Texas Medical Branch at Galveston; 2011.
  15. Subramanyam D, Gurunathan D. Microbial evaluation of plaque on 3M ESPE and kids stainless steel crown in primary molars. International Journal of Pedodontic Rehabilitation. 2016 Jul 1;1(2):60.
  16. Myers DR. A clinical study of the response of the gingival tissue surrounding stainless steel crowns. ASDC J Dent Child. 1975 Jul-Aug;42(4):281-4. Pubmed PMID: 1099129.
  17. Papathanasiou AG, Curzon ME, Fairpo CG. The influence of restorative material on the survival rate of restorations in primary molars. Pediatr Dent. 1994 Jul-Aug;16(4):282-8. Pubmed PMID: 7937261.
  18. Ram D, Peretz B. Composite crown-form crowns for severely decayed primary molars: a technique for restoring function and esthetics. J Clin Pediatr Dent. 2000 Summer;24(4):257-60. Pubmed PMID: 11314407.
  19. Fuks AB, Ram D, Eidelman E. Clinical performance of esthetic posterior crowns in primary molars: a pilot study. Pediatr Dent. 1999 Nov- Dec;21(7):445-8. Pubmed PMID: 10633519.
  20. Reeves WG. Restorative margin placement and periodontal health. J Prosthet Dent. 1991 Dec;66(6):733-6. Pubmed PMID: 1805020.
  21. Kawashima M, Hanada N, Hamada T, Tagami J, Senpuku H. Real-time interaction of oral streptococci with human salivary components. Oral Microbiol Immunol. 2003 Aug;18(4):220-5. Pubmed PMID: 12823797.
  22. Nyvad B, Kilian M. Comparison of the initial streptococcal microflora on dental enamel in caries-active and in caries-inactive individuals. Caries Res. 1990;24(4):267-72. Pubmed PMID: 2276164.
  23. Wan AK, Seow WK, Walsh LJ, Bird PS. Comparison of five selective media for the growth and enumeration of Streptococcus mutans. Aust Dent J. 2002 Mar;47(1):21-6. Pubmed PMID: 12035953.
  24. Pedrini D, Gaetti-Jardim Júnior E, de Vasconcelos AC. Retention of oral microorganisms on conventional and resin-modified glass-ionomer cements. Pesqui Odontol Bras. 2001 Jul-Sep;15(3):196-200. Pubmed PMID: 11705266.
  25. Padbury A Jr, Eber R, Wang HL. Interactions between the gingiva and the margin of restorations. J Clin Periodontol. 2003 May;30(5):379-85. Pubmed PMID: 12716328.
  26. Myers DR, Schuster GS, Bell RA, Barenie JT, Mitchell R. The effect of polishing technics on surface smoothness and plaque accumulation on stainless steel crowns. Pediatr Dent. 1980 Dec;2(4):275-8. Pubmed PMID: 6941003.

         Indexed in

pubhub  CGS  indexcoop  
j-gate  DOAJ  Google_Scholar_logo

       Total Visitors

SciDoc Counter

Get in Touch

SciDoc Publishers
16192 Coastal Highway
Lewes, Delaware 19958
Tel :+1-(302)-703-1005
Fax :+1-(302)-351-7355
Email: contact.scidoc@scidoc.org


porn